Perkins 2206A-E13TAG3 ElectropaK diesel engine for stationary prime and standby generator applications. The 12.5L inline-six configuration provides 400 kVA prime output at both rated speeds, with 450 kVA standby at 1500 rpm and 438 kVA standby at 1800 rpm. Engine rating, ECM calibration, package contents and replacement parts must be verified against the complete Build List, ESN, rated speed, duty and generator-set application.
Engine Platform:
Perkins 2206A-E13TAG3 12.5L Inline-6 Diesel
Prime Output:
400 kVA / 320 kWe
Standby Output:
450 kVA at 50 Hz / 438 kVA at 60 Hz
Speed & Frequency:
1500 rpm / 50 Hz or 1800 rpm / 60 Hz
Emissions Position:
Fuel Optimised
Build List References:
TGD5013 / TGDF5013 — Verify by Full ESN

The Perkins 2206A-E13TAG3 is a 12.5-liter, six-cylinder diesel engine developed for stationary prime and standby power generation. Supplied in ElectropaK configuration, it supports generator applications at 1500 rpm for 50 Hz systems and 1800 rpm for 60 Hz systems.

The TAG3 configuration covered on this page is typically rated at 400 kVA prime and 450 kVA standby at 1500 rpm, or 400 kVA prime and 438 kVA standby at 1800 rpm. The exact engine output, ECM calibration, Build List, supplied equipment and generator compatibility must be verified before quotation or replacement approval.

ZEB Power supplies Perkins 2206A-E13TAG3 engines and replacement parts according to the complete engine model, Build List, Engine Serial Number, rated speed, duty classification, generator-set application and destination requirements. Commercial references such as TGD5013 and TGDF5013 should be checked against the individual engine record rather than treated as automatically identical configurations.

  • 12.5 L vertical inline six-cylinder diesel engine
  • Turbocharged with air-to-air charge cooling
  • 1500 rpm / 50 Hz and 1800 rpm / 60 Hz configurations
  • 400 kVA prime output at both rated speeds
  • 450 kVA standby at 50 Hz and 438 kVA standby at 60 Hz
  • Fuel-optimised emissions position
  • Mechanically actuated unit injectors with electronic control
  • ElectropaK package for generator-set integration
  • Engine and parts matching by Build List and ESN

Send the engine dataplate, complete Build List, ESN, required frequency and duty rating to receive a configuration-specific quotation.

Perkins 2206A-E13TAG3 Technical Specifications

ParameterSpecificationSelection Note
Engine familyPerkins 2200 SeriesConfirm the complete 2206A-E13TAG3 model, Build List and ESN before replacement.
Package configurationElectropaK generator-drive engineThe engine package must be distinguished from a complete diesel generator set.
Cylinders6, vertical inlineFour-stroke diesel configuration for stationary electric-power generation.
Displacement12.5 LAlso commonly described as part of the Perkins 13-liter engine family.
Bore × stroke130 × 157 mmInternal components must be identified using the engine-specific parts record.
Compression ratio16.3:1Compression ratio alone does not identify the correct piston or overhaul part.
AspirationTurbocharged and air-to-air charge cooledThe radiator, charge cooler, fan and ambient capability must suit the completed generator set.
Combustion systemDirect injectionFuel-system components must be verified using the Build List and ESN.
Fuel controlMechanically actuated unit injectors with electronic controlECM calibration, injectors and wiring must correspond to the approved engine rating.
Rated speeds1500 rpm / 1800 rpmNormally associated with 50 Hz and 60 Hz generator applications respectively.
RotationAnti-clockwise when viewed from the flywheel endConfirm the alternator coupling and installation arrangement.
Cooling systemLiquid cooledCooling performance depends on ambient temperature, enclosure airflow and fan demand.
Total lubricating-oil capacityApproximately 40 LService filling quantity may depend on installation and drain-back conditions.
Total coolant capacityApproximately 51 LThe completed genset cooling circuit may require additional coolant.
Emissions positionFuel optimisedConfirm destination acceptance before ordering for regulated markets.
Exhaust aftertreatmentNo external aftertreatment specified for the standard engine familyLocal emissions regulations and site permits must still be reviewed.

400 kVA Prime and 438–450 kVA Standby Output

The ratings below represent the 2206A-E13TAG3 configuration covered on this page. Final output must be checked against the complete Build List, ECM calibration, official rating data, alternator efficiency, cooling arrangement and site conditions.

FrequencyEngine SpeedDutyGross Mechanical OutputNet Mechanical OutputTypical Generator Output
50 Hz1500 rpmPrime368 kWm349 kWm400 kVA / 320 kWe
50 Hz1500 rpmStandby413 kWm392 kWm450 kVA / 360 kWe
60 Hz1800 rpmPrime373 kWm349 kWm400 kVA / 320 kWe
60 Hz1800 rpmStandby407 kWm381 kWm438 kVA / approximately 350 kWe

A more accurate product positioning is 400 kVA prime with 438–450 kVA standby output, because the 1500 rpm standby configuration reaches 450 kVA.

Prime and Standby Duty

Duty RatingTypical Operating ProfilePurchasing Consideration
Prime PowerVariable load with extended annual operationConfirm the average load factor, overload allowance, annual operating hours and applicable rating definition.
Standby PowerEmergency operation during failure of the normal electrical sourceThe standby rating should not be selected for continuous base-load operation.

Prime Fuel Consumption

The following figures are reference values for the published TAG3 prime ratings. Actual site consumption depends on load profile, alternator efficiency, fan power, ambient temperature, altitude, fuel quality and generator-set installation.

Engine SpeedPrime Rating100% Load75% Load50% Load
1500 rpm349 kWm net / 400 kVA197 g/kWh199 g/kWh202 g/kWh
1800 rpm349 kWm net / 400 kVA196 g/kWh199 g/kWh205 g/kWh

50 Hz and 60 Hz Configuration

The 2206A-E13TAG family supports 1500 rpm and 1800 rpm frequency configurations. However, engine switchability should not be interpreted as permission to change every completed generator set between 50 Hz and 60 Hz through one controller setting.

The ECM calibration, AC alternator, voltage arrangement, generator controller, circuit breakers, cooling package and connected loads must all support the proposed frequency before conversion.

System AreaRequired VerificationPossible Risk
Engine ECM and ratingConfirm approved 1500 rpm and 1800 rpm calibrations for the Build ListIncorrect output, governing or engine-protection behavior
AC alternatorConfirm frequency, voltage, pole arrangement and thermal ratingIncorrect voltage, overheating or inability to produce the required frequency
Generator controllerConfirm speed control, frequency sensing and protection settingsOverspeed, underspeed or protection faults
Cooling packageConfirm fan speed, radiator capacity and ambient rating at both engine speedsInsufficient cooling or excessive fan-power demand
Connected equipmentConfirm whether motors and electrical loads accept the new frequency and voltageEquipment damage or incorrect operating speed

Standard ElectropaK Supply Scope

The ElectropaK is an engine package prepared for generator-set integration. It is not automatically a complete diesel generator set. The main AC alternator, generator controller, fuel tank, base frame and acoustic enclosure are normally supplied separately unless included in the quotation.

SystemTypical ElectropaK EquipmentConfirmation Required
Air inletEngine-mounted air cleanerConfirm rain hood, restriction indicator and enclosure-air requirements.
Cooling circulationGear-driven coolant-circulation pumpConfirm hose connections and the final cooling-circuit arrangement.
Cooling fanEngine-driven fan and fan guardConfirm fan specification, rotation, clearance and absorbed power.
Radiator and charge coolerRadiator package incorporating air-to-air charge coolingConfirm whether the radiator is mounted or supplied separately.
Starting system24 V starter motorConfirm battery quantity, capacity, cables and any twin-starter option.
Charging system24 V battery-charging alternatorConfirm the output rating against the actual Build List.
Electronic controlsEngine-mounted ECM, sensors and wiring harnessesConfirm calibration, connectors and generator-controller compatibility.
Flywheel and housingGenerator-drive flywheel and housing configurationConfirm the SAE interface, coupling and torsional compatibility.
Fuel systemMechanically actuated, electronically controlled unit injectorsConfirm injector references, fuel connections and ECM calibration.
Fuel filtrationEngine-mounted filter and water-separation arrangementConfirm whether additional base-mounted filtration is required.
Lubrication systemWet sump, full-flow filtration and integrated oil coolingConfirm sump orientation, oil specification and service interval.
Engine mountingMounting brackets for generator-set integrationCompare actual mounting dimensions with the proposed base frame.

Common Optional Equipment

  • 110 V or 240 V coolant immersion heater
  • Additional engine-speed sensor
  • Air-cleaner rain hood
  • Additional temperature and pressure sensors
  • Twin-starting arrangement or provision for a second starter
  • Application-specific tool kit

ElectropaK Dimensions and Installation Data

ParameterTypical ValueInstallation Note
Length2410 mmFinal length depends on the selected options and radiator arrangement.
Width1120 mmAllow additional space for service access and enclosure airflow.
Height1725 mmConfirm lifting, installation and canopy-clearance requirements.
Dry weightApproximately 1478 kgFinal engine and packed weights depend on options, fluids and loose equipment.

These dimensions should not be used to design the base frame or enclosure without an approved general-arrangement drawing for the actual Build List and package specification.

Build List and Engine Serial Number Verification

The Build List and Engine Serial Number identify the individual factory configuration. Record them from the engine dataplate before ordering a replacement engine, ECM, injector, piston, bearing set, pump or other critical component.

Identification ItemWhat It ConfirmsHow It Should Be Used
Complete engine modelThe 2206A-E13TAG3 model familyConfirms the general platform but not every option, rating or calibration.
Build ListThe factory configuration, rating and installed componentsUse as the primary reference for engine and parts matching.
Engine Serial NumberThe individual engine-production recordUse to verify production changes, superseded parts and service history.
Rated speedThe approved 1500 rpm or 1800 rpm configurationConfirms the intended frequency and power group.
ECM referenceThe electronic-control hardware and calibration familyRequired for ECM replacement or a proposed rating change.
Generator-set serial numberThe completed assembly built by the genset manufacturerUse when replacing the engine in an existing generator set.

TGD5013 and TGDF5013

TGD5013 and TGDF5013 both appear in the commercial information supplied for this product page. They should not be described as universally identical or fully parts-compatible solely because they are associated with the same model designation.

Before supply, verify the Build List exactly as stamped on the engine plate, the full ESN, rated speed, power rating, ECM information and current parts data. For a replacement engine, also compare the flywheel housing, engine mounts, wiring interface, radiator arrangement and generator-set controls.

2206A-E13TAG2 and TAG3 Comparison

The TAG2 and TAG3 share the 12.5-liter Perkins 2200 Series platform, but their 1500 rpm ratings are not identical. The TAG3 increases the 50 Hz prime and standby power nodes, while the published 1800 rpm TAG2 and TAG3 ratings are the same.

Model1500 rpm Prime1500 rpm Standby1800 rpm Prime1800 rpm Standby
2206A-E13TAG2350 kVA400 kVA400 kVA438 kVA
2206A-E13TAG3400 kVA450 kVA400 kVA438 kVA

2206A, 2206C and 2206D Comparison

The 2206A, 2206C and 2206D engines share the Perkins 2200 Series foundation, but they occupy different emissions and output positions. They should not be treated as direct substitutes based only on displacement, appearance or the TAG3 suffix.

Engine FamilyEmissions PositionTypical Family OutputReplacement Consideration
2206A-E13TAGFuel optimisedApproximately 350–500 kVAConfirm destination acceptance, TAG model, speed, Build List and ECM calibration.
2206C-E13TAGEU Stage II / U.S. EPA Tier 2Approximately 350–438 kVAConfirm the exact TAG rating, Build List, electronic controls and installation interfaces.
2206D-E13TAGEU Stage IIIA / U.S. EPA Tier 3 / China IIIApproximately 400–500 kVAConfirm emissions acceptance, rated speed, output and complete engine configuration.

The A, C and D generations do not have universally identical outputs or parts compatibility. Build List, ESN, ECM calibration, rated speed, emissions position and installed equipment must all be checked before substitution.

Replacement Engine Matching

Replacement CheckRequired ComparisonPossible Mismatch
Engine ratingPrime, standby, rated speed and mechanical outputInsufficient electrical output or engine overload
Flywheel and housingSAE size, flywheel inertia and coupling arrangementThe alternator cannot be connected correctly
Engine mountsFront and rear mounting dimensionsBase-frame modification may be required
Cooling systemRadiator, fan, charge cooler and ambient ratingOverheating or excessive parasitic power
ECM and wiringHarness connectors, customer interface and controller communicationStarting, governing or protection functions may not operate correctly
Exhaust systemTurbocharger outlet, exhaust connection and back-pressure limitInstallation changes or excessive exhaust restriction
Air intakeFilter position, intake restriction and enclosure ventilationReduced output or elevated intake temperature
Emissions acceptanceDestination regulations and site-permit requirementsThe fuel-optimised engine may not be accepted in a regulated market

Perkins 2206A-E13TAG3 Replacement Parts

Replacement parts are available for routine maintenance, repair and overhaul. Exact part numbers must be verified through the Build List and ESN because multiple component versions or superseded references may be used within the 2206 engine family.

Parts GroupTypical ComponentsIdentification Required
Cylinder headValves, springs, collets, guides, seats, seals and related hardwareBuild List, ESN and cylinder-head reference
Piston and connecting rodPistons, rings, pins, retainers, connecting rods and small-end componentsBuild List, piston reference and connecting-rod number
Crankshaft bearingsMain bearings, connecting-rod bearings and thrust washersBuild List, existing markings and crankshaft measurements
Camshaft and valve trainCamshaft, bushes, followers, rocker components and related partsBuild List, installed reference and inspection findings
Fuel systemUnit injectors, fuel filters, priming pump and water-separation componentsESN, injector reference and fuel-system configuration
Electronic controlsECM, sensors, wiring harnesses and speed-control componentsECM reference, calibration, connectors and Build List
Starting and chargingStarter motor, charging alternator, belts and electrical componentsSystem voltage, Build List and installed part number
Lubrication systemOil pump, oil cooler, filter head, filters and pressure-control componentsBuild List and installed-component reference
Cooling systemWater pump, thermostats, fan, belts, radiator and charge-cooler componentsBuild List, radiator arrangement and ambient requirement
Gaskets and sealsUpper gasket sets, lower gasket sets, crankshaft seals and application sealsRepair scope, Build List and current parts information
Routine maintenanceOil, fuel and air filters, belts and service consumablesESN, maintenance schedule and installed filtration arrangement

A fixed parts-number list should not be approved without an ESN check. A part listed for one TGD or TGDF engine may not be correct for every engine carrying the same model designation.

Engine Condition and Supply Scope

Supply ConditionDescriptionRequired Documentation
New Genuine PerkinsNew engine supplied through a documented sales channelDataplate, ESN, Build List, supply source and applicable manufacturer documents
Genuine Unused StockUnused engine held in distributor or project inventoryManufacturing date, storage history, preservation status and warranty terms
Genuine SurplusUnused or low-hour engine released from an excess or cancelled projectCondition report, ESN, operating hours where applicable and source documentation
RemanufacturedEngine rebuilt to a declared remanufacturing specificationRebuild BOM, machining records, test report, component source and warranty
Used EnginePreviously operated engine supplied in tested or as-is conditionOperating hours, inspection results, test records, fault history and exclusions

Pre-Shipment Verification

Verification ItemRequired CheckRecord When Agreed
Engine identityModel, Build List, ESN and dataplate comparisonDataplate and serial-number photographs
Rated configurationSpeed, frequency, duty, power rating and ECM informationRating sheet or configuration record
Package contentsRadiator, air cleaner, starter, charging alternator, ECM, flywheel and loose itemsPacking list and pre-shipment photographs
External conditionLeaks, corrosion, transport damage, missing components and connector conditionInspection photographs
Electrical systemStarter, charging system, sensors, harness and ECM communicationElectrical inspection or diagnostic record
Operational testStarting, oil pressure, coolant temperature, speed control, smoke and abnormal noiseTest report or video when included in the order
PreservationFluid status, corrosion protection and preparation for transport or storagePreservation and storage instructions

Information Required for a Quotation

  • Complete engine model: 2206A-E13TAG3
  • Clear photograph of the engine dataplate
  • Complete Build List
  • Full Engine Serial Number
  • Required speed: 1500 rpm or 1800 rpm
  • Required frequency: 50 Hz or 60 Hz
  • Prime or standby duty
  • Required generator output
  • Replacement-engine or new-project application
  • Generator-set manufacturer and model when replacing an engine
  • Required engine condition and package contents
  • Destination port and delivery address
  • Required emissions, certification and shipping documents

Packing and International Shipping

Supply ItemAvailable ArrangementConfirmation Point
Internal protectionProtected openings, electrical connectors and loose componentsDepends on the supplied ElectropaK configuration.
Corrosion protectionProtective oil, sealed components and storage preservationConfirm for sea freight and long-term storage.
Export packingHeavy-duty wooden case or skid with secured engine and accessoriesFinal design depends on dimensions, radiator arrangement and shipping route.
Shipping methodLCL, FCL, flat-rack or another suitable freight arrangementSelect according to packed dimensions, weight, urgency and destination.
Trade termsEXW, FOB, CFR, CIF, DAP or other agreed termsSubject to destination, customs requirements and final quotation.
Export documentsCommercial invoice, packing list and agreed transport documentsCertificate of origin and additional customs documents depend on the transaction.

Stock status, lead time, packed weight, shipping dimensions and freight cost should only be confirmed after the exact engine, Build List, condition, quantity and destination have been approved.

Perkins 2206A-E13TAG3 engine prepared for export packingPerkins generator engine secured for international shipmentPerkins 2206 engine and loose components protected for export delivery
Perkins 2206A-E13TAG3 replacement parts prepared for delivery

Warranty and After-Sales Records

Warranty coverage depends on the engine condition, supply source, commissioning procedure, operating application and final contract. New genuine, unused-stock, remanufactured and used engines should not be advertised with one automatic warranty period.

Required RecordWhy It Matters
Final quotation and supplied configurationDefines the engine condition, included equipment, rating and contractual warranty.
Dataplate, Build List and ESNConfirms the identity of the supplied engine.
Installation and alignment recordsShows that the engine, alternator and base frame were installed correctly.
Fuel, oil and coolant recordsConfirms the use of suitable fluids and clean systems.
Commissioning reportRecords oil pressure, temperature, frequency, voltage, load response and diagnostic codes.
Operating-hour and maintenance recordsSupports failure analysis and warranty review.
Transit inspectionSeparates transport damage from installation or operating faults.

Frequently Asked Questions

What output does the 2206A-E13TAG3 provide?

The TAG3 configuration is typically rated at 400 kVA prime and 450 kVA standby at 1500 rpm, or 400 kVA prime and 438 kVA standby at 1800 rpm. Confirm the exact output using the complete Build List and official rating data.

Why does the 50 Hz standby rating differ from the 60 Hz standby rating?

The published 1500 rpm configuration produces 450 kVA standby, while the 1800 rpm configuration produces 438 kVA standby. The difference results from the approved engine calibration and mechanical output at each rated speed.

Does the engine support both 50 Hz and 60 Hz?

The 2206A family supports 1500 rpm and 1800 rpm configurations. A completed generator set must still be checked for alternator, controller, voltage, cooling and connected-load compatibility.

Are TGD5013 and TGDF5013 completely identical?

This should not be assumed without reviewing the individual engine record. Confirm the Build List exactly as stamped on the dataplate, the complete ESN, rating, ECM information and current parts data before ordering.

What is the difference between TAG2 and TAG3?

At 1500 rpm, the TAG3 increases output from 350/400 kVA to 400/450 kVA. At 1800 rpm, the published TAG2 and TAG3 ratings are both 400 kVA prime and 438 kVA standby.

What does the “A” in 2206A-E13TAG3 indicate?

The A-generation is positioned as fuel optimised rather than under the regulated emissions levels used for the C- and D-generation engines. Destination emissions acceptance should be confirmed before ordering.

Can a 2206C or 2206D replace a 2206A directly?

Not without verification. Compare output, emissions acceptance, ECM and wiring, flywheel housing, mounts, cooling package, exhaust arrangement and generator controls.

Is ElectropaK a complete generator set?

No. It is an engine package prepared for generator-set integration. The main AC alternator, controller, base frame, fuel tank and acoustic enclosure are normally supplied separately unless included in the quotation.

Does the ElectropaK include a radiator?

The engine family is offered with a radiator and air-to-air charge-cooling package. The exact radiator specification and whether it is mounted or supplied separately must be confirmed in the final supply scope.

Can I order the engine or parts using only the model name?

No. Provide the complete Build List and ESN together with the required speed, frequency, duty and generator-set application.

Are fixed part numbers valid for every TGD or TGDF engine?

No. Different component versions or superseded references may be used within one model family. Critical parts must be verified through the Build List and ESN.

What is the fuel consumption?

Published prime fuel-consumption values range from approximately 196 to 205 g/kWh depending on speed and load percentage. Actual generator-set consumption varies with load profile, alternator efficiency, fan demand and site conditions.

What fuel and lubricating oil should be used?

Use fuel, oil viscosity, performance category and service intervals that comply with the applicable Perkins Operation and Maintenance Manual, ambient conditions, fuel quality and operating duty.

Is a new engine always supplied with a manufacturer warranty?

Warranty depends on the engine condition, supply source, regional sales channel and final contract. The quotation should identify the warranty provider, start date, duration, operating-hour limit and exclusions.

Can individual Perkins 2206A parts be supplied?

Yes. Cylinder-head parts, pistons, rings, bearings, unit injectors, ECM components, starter motors, pumps, filters, belts and cooling-system parts can be supplied after Build List and ESN verification.

Request a 2206A-E13TAG3 Configuration Check

An engine-specific configuration check helps prevent mismatched ratings, ECM calibrations, alternator interfaces, cooling packages and replacement parts. The complete Build List and ESN should be verified before an order is released.

Contact ZEB Power for Perkins 2206A-E13TAG3 identification, Build List verification, replacement parts, export packing and international delivery.

Get Your Engine & Parts Quote
Upload your parts list or send your ESN — we reply within 30 minutes. Engine down? Need fast replacement? Contact us to check today’s stock & delivery time.
Your name *
Email *
WhatsApp / Wechat / Skype
Country
Engine Serial Number or Parts List *

sales@zebpower.com

86 13420993392

+8613420993392