Perkins 4012-46TAG0A Genset Engine – 1250–1375 kVA
Perkins 4012-46TAG0A Genset Engine – 1250–1375 kVA

Perkins 4012-46TAG0A Genset Engine – 1250–1375 kVA

The Perkins 4012-46TAG0A is a 45.842L V12 engine for 1500 rpm / 50 Hz generator sets rated at 1250 kVA Prime and 1375 kVA Standby. Original DGLM6235S, DGLM0106S and DGLM1571S Build Lists correspond to the later DGL shortened designations, but the complete ESN remains required for configuration and parts verification. Confirm the cooling package, governor and actuator interfaces, supply scope and applicable drawing before ordering.
1500 rpm / 50 Hz Rating:
1250 kVA / 1000 kWe Prime · 1375 kVA / 1100 kWe Standby
Engine Architecture:
45.842L V12 at 60° · Turbocharged · Air-to-Air Charge Cooled
Build Verification:
DGLM6235S / DGLM0106S / DGLM1571S · Complete ESN Required
Control Architecture:
Electronic Governor and Actuator · No Engine-Mounted ECM
Tropical Package:
2269 × 3915 × 2200 mm · 5690 kg Dry Weight · Temperate Data to Be Confirmed
Service & Fluid Capacity:
500-Hour Stated Service Interval · 157.5 L Oil · 223 L Coolant

The Perkins 4012-46TAG0A is a 45.842-litre V12 diesel engine for high-output 1500 rpm / 50 Hz generator sets. Its published ratings are 1250 kVA prime and 1375 kVA standby, corresponding to 1000 kWe and 1100 kWe at a stated power factor of 0.8.

This model belongs to the heavy-duty Perkins generator-drive engine range and is supplied around an Electro unit or ElectropaK configuration. It uses turbocharging, air-to-air charge cooling, individual four-valve cylinder heads and unit fuel injectors. Correct selection requires confirmation of the complete DGL/DGLM Build List, ESN, cooling package, governor and actuator arrangement, package scope and destination requirements.

Start with the 1250–1375 kVA Rating Boundary

The 4012-46TAG0A has separate prime and standby ratings at 1500 rpm. These ratings describe different operating duties and should not be treated as interchangeable output labels.

DutyGross Engine PowerNet Engine PowerGenerator OutputElectrical Output
Prime1125 kW (1509 hp)1053 kW (1412 hp)1250 kVA1000 kWe
Standby1230 kW (1649 hp)1158 kW (1552 hp)1375 kVA1100 kWe

Prime and Standby Describe Different Operating Profiles

The 1250 kVA prime rating applies to the approved variable-load or regular operating profile of the complete generator set. The 1375 kVA standby rating is the higher emergency-power level and remains subject to the operating-hour and loading limits of the applicable standby classification.

A project expecting frequent generator operation should not be sized only from the 1375 kVA standby figure. Annual operating hours, expected load variation, redundancy requirements and the largest load steps should be defined before the engine and alternator are selected.

A Dedicated 1500 rpm / 50 Hz Engine

The supplied product information identifies the 4012-46TAG0A exclusively as a 1500 rpm configuration. No approved 1800 rpm / 60 Hz rating is provided for this model.

A 60 Hz project therefore requires a separately documented engine platform. The governed speed should not be changed in the field in an attempt to convert this engine to another frequency.

Frequency DecisionRequirement
50 Hz ProjectUse the approved 1500 rpm DGL/DGLM configuration
60 Hz ProjectSelect a separately documented 1800 rpm engine
Existing Engine ReplacementConfirm rated speed from the engine nameplate and genset documentation
Frequency ConversionDo not approve from the model name or advertised kVA alone

Build Lists DGLM6235S, DGLM0106S and DGLM1571S

The principal original Build List designations are DGLM6235S, DGLM0106S and DGLM1571S. The supplied information identifies them as Perkins designations assigned in 2008 for the same stated 4012-46TAG0A engine specification.

DGL6235S, DGL0106S and DGL1571S are the corresponding shortened designations used for engines from later production batches.

Build List GroupIdentificationPage Rating
DGLM6235S / DGLM0106S / DGLM1571SOriginal Perkins designations1250 kVA prime / 1375 kVA standby at 1500 rpm
DGL6235S / DGL0106S / DGL1571SUpdated shortened designations for later batchesSame stated engine specification

The source treats the original and updated designations as equivalent for the stated specification and parts compatibility. The complete Engine Serial Number is still required because it identifies the production record, installed equipment and component revisions of the individual engine.

Information to Record from the Engine Nameplate

  • Complete model: 4012-46TAG0A
  • Complete Build List beginning with DGL or DGLM
  • Complete Engine Serial Number
  • Rated speed: 1500 rpm
  • Cooling configuration: tropical or temperate when known
  • Governor and actuator arrangement
  • Original generator-set manufacturer and model

The nameplate is normally mounted on the rocker-cover or timing-case area. A clear photograph of the entire plate is preferable to a manually copied Build List or serial number.

The Build List Defines More Than the Power Rating

The Build List and ESN are used together to confirm the cooling package, governor and actuator arrangement and factory-installed equipment. Two engines carrying the same base model name should not be assumed to have identical peripheral equipment.

Configuration AreaWhy Build Verification Matters
Cooling PackageTemperate and tropical versions may use different radiators, fans and package dimensions
Governor and ActuatorControl hardware and interfaces must match the original generator-set control system
Factory-Fitted EquipmentFilters, brackets, sensors, harnesses and accessories may vary by build
Replacement PartsPart-number alternatives must be resolved against the complete ESN
Replacement EngineMounting, cooling, exhaust and control interfaces must be compared with the existing unit

Electronic Governor and Actuator Without an Engine-Mounted ECM

The supplied technical specification identifies electronic governor and actuator control but states that there is no engine-mounted ECM. This control architecture requires particular attention during generator-set integration.

The genset builder should not assume that the engine contains a complete engine-mounted electronic control module with all start, stop, protection and communication functions. The governor, actuator, speed sensing, shutdown circuits and generator-set controller interfaces must be reviewed as a complete system.

Control InterfaceIntegration Check
GovernorConfirm governor model, power supply and speed-control interface
ActuatorConfirm actuator type, linkage, response and supplied harness
Speed SignalConfirm magnetic pickup or applicable speed-sensing arrangement
Start and Stop LogicConfirm how the genset controller commands starting and shutdown
Engine ProtectionConfirm oil-pressure, coolant-temperature, overspeed and emergency-stop circuits
Parallel OperationConfirm load-sharing and synchronization interfaces with the governor system
Customer WiringObtain the wiring diagram for the exact Build List and package scope

Electro Unit and ElectropaK Are Different Commercial Scopes

The specification lists Electro unit / ElectropaK configurations, while the introductory product information positions the engine as an ElectropaK supply. The exact package scope should therefore be stated in the quotation rather than inferred from the model name.

Package DescriptionScope to Confirm
Electro UnitIncluded engine accessories, cooling exclusions and applicable dimensional drawing
ElectropaKRadiator, fan system, filtration, controls, mounts and included engine equipment
Complete Generator SetAlternator, controller, base frame, breaker, enclosure and fuel system
Replacement Engine PackageCompatibility with the existing radiator, base, coupling, exhaust and control panel

Package descriptions should be accompanied by a written inclusion list. A buyer should not assume that the alternator, base frame, circuit breaker, enclosure or external fuel system is included with an ElectropaK.

Tropical and Temperate Cooling Packages

The source identifies tropical and temperate cooling configurations. Their dimensions and weight should not be presented as identical.

The stated tropical-package dimensions are 2269 × 3915 × 2200 mm, with a stated dry weight of 5690 kg. Temperate-package dimensions and weight are not confirmed in the supplied information.

Cooling VersionDimensions (H × L × W)Dry WeightData Status
Tropical Version2269 × 3915 × 2200 mm5690 kgProvided in the source page
Temperate VersionTo be confirmedTo be confirmedNot supplied in the source page

The tropical dimensions should not be applied automatically to a temperate unit. Confirm the complete Build List and obtain the corresponding general-arrangement drawing before foundation, enclosure or transport planning is finalised.

Cooling-System Information Required for Project Release

  • Tropical or temperate package selection
  • Maximum site ambient temperature
  • Site altitude and expected derating
  • Radiator model and fan-drive arrangement
  • Cooling-air inlet and hot-air discharge route
  • Permitted enclosure pressure restriction
  • Coolant specification and expansion arrangement
  • Service access to radiator, hoses and water pumps

V12 Mechanical Platform

The 4012-46TAG0A uses a 12-cylinder, 60-degree vee architecture with a displacement of 45.842 litres. At this scale, foundation loading, lifting access, engine-room ventilation and long-term service access must be treated as primary design inputs.

Mechanical ParameterSpecification
Model4012-46TAG0A
ConfigurationElectro unit / ElectropaK
Cylinder Arrangement12 cylinders, 60° vee
Displacement45.842 L (2979 in³)
Bore × Stroke160 × 190 mm (6.3 × 7.5 in)
AspirationTurbocharged, air-to-air charge cooled
Combustion SystemDirect injection
Compression Ratio12.8:1
Rotation Viewed from FlywheelAnti-clockwise
Control SystemElectronic governor and actuator; no engine-mounted ECM
Cooling SystemWater cooled
Total Lubricating-Oil Capacity157.5 L (41.6 US gal)
Total Coolant Capacity223 L (58.9 US gal)
Exhaust AftertreatmentN/A in the supplied specification

Installation Decisions for a 1.375 MVA-Class Package

A V12 generator-drive package requires more than checking whether the engine fits between the walls of the generator room. The complete service and removal route should be reviewed before the foundation and enclosure are released.

Installation AreaInformation to Confirm
FoundationStatic load, dynamic considerations, mounting arrangement and levelling
Access RouteDoor width, roof access, crane capacity and future engine-removal path
Alternator IntegrationAlternator frame, coupling, alignment, power factor and package rating
Cooling AirRadiator airflow, inlet area, discharge ducting and recirculation risk
ExhaustPipe size, support, thermal expansion and permissible back pressure
Fuel SystemDay tank, transfer system, return routing, filtration and fuel quality
Electrical ControlGovernor, actuator, sensors, shutdown circuits and panel interface
Maintenance AccessClearance around cylinder heads, injectors, filters, pumps and manifolds

Individual Four-Valve Cylinder Heads

Each cylinder uses an individual four-valve cylinder head. This arrangement supports gas flow and allows cylinder-level head work without treating the entire V12 engine as a single cylinder-head assembly.

The wider Perkins 4000 Series shares design principles and certain component families, but this should not be interpreted as universal interchangeability between 4006, 4008, 4012 and 4016 engines. Every part must still be checked against the exact engine record.

Unit Fuel Injectors and Build-Specific Parts

Unit fuel injectors support fuel atomisation and controlled combustion. The injector reference listed for the DGL/DGLM6235S family is 858/35.

Injectors, pistons, valves, connecting rods, manifolds and filtration components should not be selected from the general “4012” description. Final part numbers should be released only after the complete Build List and ESN have been verified.

Service Planning and Fluid Capacity

The source states a 500-hour oil and fuel service interval. The applicable Perkins Operation and Maintenance Manual should still be used to confirm the precise tasks, fluid specifications and any interval adjustments for the individual engine and its operating environment.

Service ItemPlanning Requirement
Stated Oil and Fuel Service Interval500 operating hours
Lubricating-Oil Capacity157.5 L (41.6 US gal)
Coolant Capacity223 L (58.9 US gal)
Oil SpecificationConfirm from the manual applicable to the exact DGL/DGLM Build List
Fuel-Service ScopeConfirm filters, water separation and site fuel-quality requirements
Severe ConditionsReview dust, high ambient temperature, fuel quality and prolonged low-load operation
Waste-Fluid HandlingPlan collection and disposal around the large oil and coolant volumes

Exhaust Aftertreatment and Destination Compliance

The technical specification lists exhaust aftertreatment as N/A. This indicates that no aftertreatment system is stated in the supplied configuration.

It should not be interpreted as confirmation that the engine complies with every regional emissions limit. Destination regulations, tender requirements and supporting emissions documentation must be confirmed before quotation or shipment.

Application Review

The 4012-46TAG0A may be evaluated for high-output prime and standby power projects. The project should be assessed through the actual load behaviour rather than only the total connected load.

Project TypeKey Information to Confirm
Industrial FacilityMotor starts, compressor demand, process sequencing and permitted interruption
Critical Backup ProjectTransfer sequence, priority loads, redundancy and expected standby hours
Large Commercial FacilityLifts, pumps, ventilation, fire systems and priority-load distribution
Data or Communications FacilityUPS interaction, cooling demand, staged transfer and redundancy architecture
Parallel Generator PlantSynchronization, protection, governor compatibility and load-sharing strategy

Parallel Operation Requires Full Control-System Review

Generator sets using the 4012-46TAG0A may be incorporated into a parallel system when the complete packages have compatible controllers, alternators, voltage regulators, protection settings, synchronization equipment and governor interfaces.

Parallel capability is not established by the engine model alone. Load sharing, breaker coordination, maximum load step and synchronization sequence must be validated by the genset integrator.

Original Perkins Replacement Parts

The following references are listed as original Perkins components for the DGL/DGLM6235S Build List family. Additional Perkins engine parts can be reviewed by component category, but final confirmation should be based on the complete ESN.

ItemPart NamePart Number
1Intake and Exhaust ValveSE7AG/14, SE7AJ/14
2Small End BushSE91B/7 or Y01/00023
3Valve GuideT401899
4Valve Spring365/472
5Valve ColletHW7B/18
6Fuel FilterSE429B/4 or 4759205
7Exhaust Manifold12SE15AA, 12SE15W, 12SE15U, 12SE15Y
8Air Filter AssemblySEV551N
9Connecting Rod AssemblySEV91Q
10Big End Bearing KitSE91AA/3M
11Piston and Ring KitSE901BA
12Piston Ring Kit359/552
13Starter Motor701/134 or 701/137
14Alternator Belt541/398
15Injector858/35
16Oil Pump12SE116C
17Oil Filter4324909 / SE111B
18Water Pump KitSE145AY / SE145H

Several component groups contain more than one possible reference. Do not select between alternatives by appearance, dimensions or the generic 4012 model name. Confirm the complete DGL/DGLM Build List and ESN before releasing the final part number and quantity.

perkins engine parts warehouse engine parts warehouse
Perkins engine service Perkins engine service

Procurement and Export Release

Availability should be confirmed when the inquiry is submitted. The stated lead time is typically 3–4 weeks, and quotations are provided within 24 hours after the configuration, quantity and delivery terms have been defined.

Procurement ItemSupply Information
Supply SourceGenuine Perkins through a first-tier authorised distributor channel
Quotation BasisBuild List, ESN, cooling package, supply scope, quantity and delivery terms
Quotation TimeWithin 24 hours after receiving complete inquiry information
Typical Lead Time3–4 weeks, subject to availability confirmation
Pre-Shipment VerificationESN and engine nameplate checked before dispatch
Engine Test ReportAvailable on request
Export DocumentsCommercial invoice, packing list, bill of lading and certificate of origin
ShippingFCL or LCL from Shenzhen, Guangzhou or Shanghai
PackagingCrating and export packaging included
Export ExperienceSupplied to more than 30 countries
CAT C15 engine shipping CAT engine shipping Perkins engine shipping
engine parts delivering

Warranty and Technical Claim Review

The stated warranty period is 12 months or the manufacturer-specified operating hours from the commissioning date, whichever occurs first. Final coverage should be confirmed against the complete engine serial number, application and applicable warranty terms.

Conditions Outside Warranty Coverage

  • Incorrect installation or improper commissioning
  • Failure to follow the applicable Perkins Operation and Maintenance Manual
  • Normal consumption of filters, belts, coolant and lubricants
  • Damage caused by contaminated fuel or an incorrect lubricant specification
  • Cooling-system neglect
  • Unauthorised modifications or repairs during the warranty period
  • Transit damage not reported within three working days of delivery

Information Required for Technical Review

  • Complete Build List and ESN
  • Current operating hours
  • Prime or standby application
  • Fault description and operating conditions
  • Available fault codes
  • Photographs of the affected area
  • Relevant commissioning and maintenance records

The stated technical-review time is within two business days after the required evidence has been received. Depending on the assessment, the response may include replacement parts, coordinated repair support or an engine exchange.

Transit Damage Procedure

Inspect the shipment before signing the delivery receipt. Photograph visible damage before unpacking, record it on the receipt and notify the supplier within three working days. Do not commission a visibly damaged engine before the transport-damage report has been reviewed.

Perkins 4012-46TAG0A FAQ

What is the published generator-set rating?

At 1500 rpm, the published ratings are 1250 kVA prime and 1375 kVA standby, corresponding to 1000 kWe and 1100 kWe.

Which Build Lists apply to this page?

The original designations are DGLM6235S, DGLM0106S and DGLM1571S. The corresponding shortened designations are DGL6235S, DGL0106S and DGL1571S.

Can the engine operate at 1800 rpm / 60 Hz?

No approved 1800 rpm / 60 Hz rating is provided. The supplied information identifies the model only as a 1500 rpm / 50 Hz configuration.

Does the engine have an engine-mounted ECM?

The supplied specification states that the engine uses electronic governor and actuator control without an engine-mounted ECM. The external control and protection interfaces must therefore be reviewed with the genset panel.

Which package dimensions are confirmed?

The stated tropical-package dimensions are 2269 × 3915 × 2200 mm with a dry weight of 5690 kg. Temperate-package dimensions and weight are not confirmed in the supplied information.

What is the stated service interval?

The source states a 500-hour oil and fuel service interval. The applicable Perkins manual should define the exact operations and fluid requirements.

Does N/A aftertreatment confirm emissions compliance?

No. It indicates that no exhaust-aftertreatment system is stated in the supplied specification. Destination emissions requirements must still be confirmed.

What information is required for a quotation?

Provide the complete model, Build List, ESN, cooling package, duty, supply scope, genset information, quantity, destination and required documents.

Request a 4012-46TAG0A Configuration Review

Submit the following through the engine inquiry and quotation page:

  • Complete DGL or DGLM Build List
  • Complete ESN or a clear photograph of the nameplate
  • Prime or standby duty requirement
  • Confirmation of 1500 rpm / 50 Hz operation
  • Tropical or temperate cooling requirement
  • Electro unit or ElectropaK supply requirement
  • Governor, actuator and control-panel information
  • Alternator output, voltage and power factor
  • Maximum site temperature and altitude
  • Original generator-set manufacturer and model for replacement projects
  • Quantity, delivery terms and destination port
  • Required emissions, export, test and warranty documentation

Related Product