Follow Us:
Español Pусский Français English
Perkins 2806A-E18TAG2 ElectropaK Genset Engine – 625–700 kVA
Perkins 2806A-E18TAG2 ElectropaK Genset Engine – 625–700 kVA

Perkins 2806A-E18TAG2 ElectropaK Genset Engine – 625–700 kVA

The Perkins 2806A-E18TAG2 is a Fuel Optimised ElectropaK engine for prime and standby generator-set applications. The 1500 rpm / 50 Hz and 1800 rpm / 60 Hz versions are separate factory builds, so the required frequency, rated speed, Build List and complete ESN must be confirmed before approving an engine replacement or parts order. Standard wiring terminates at the engine ECM; a single customer-interface harness is not integrated.
Engine Configuration:
18.1L Inline-6 · Parallel Twin-Turbo · Air-to-Air Aftercooled
1500 rpm / 50 Hz Output:
650 kVA / 520 kWe Prime · 700 kVA / 560 kWe Standby
1800 rpm / 60 Hz Output:
625 kVA / 500 kWe Prime · 687 kVA / 550 kWe Standby
Emissions Category:
Fuel Optimised (A) · Non-Emissions-Regulated Build
Build Identification:
JGBF8028 / JGB8028 · Complete ESN Required for Verification
Dimensions / Dry Weight:
1808 × 2545 × 1536 mm · 2050 kg

The Perkins 2806A-E18TAG2 is an 18.1-litre, six-cylinder ElectropaK diesel engine for prime and standby generator sets. As part of the wider Perkins generator-drive engine range, it uses parallel turbocharging, air-to-air aftercooling and direct injection to deliver high output from the Perkins 2800 Series industrial platform.

Build List JGBF8028 / JGB8028 covers separate 1500 rpm and 1800 rpm factory builds. The 1500 rpm version is rated at 650 kVA prime and 700 kVA standby for 50 Hz applications, while the 1800 rpm version is rated at 625 kVA prime and 687 kVA standby for 60 Hz applications. These are not field-switchable speed settings, so the required frequency, rated speed, Build List and complete Engine Serial Number (ESN) should be confirmed before ordering.

Perkins 2806A-E18TAG2 Technical Specifications

ParameterValue
ConfigurationElectropaK
Cylinders6, vertical in-line
Displacement18.1 L (1104 in³)
Bore × Stroke145 × 183 mm
AspirationParallel turbocharged, air-to-air aftercooled
Combustion SystemDirect injection
Compression Ratio14.5:1
Rotation Viewed from FlywheelAnti-clockwise
Total Lubricating Oil Capacity62 L (16.4 US gal)
Cooling SystemWatercooled
Total Coolant Capacity61 L (16.1 US gal)
Dry Weight2050 kg (4520 lb)
Dimensions (H × L × W)1808 × 2545 × 1536 mm
Wiring Harness to Single Customer InterfaceNot integrated — connector wiring to ECM only

Power Ratings at 1500 rpm and 1800 rpm

The two rated-speed versions have different generator outputs and must be selected according to the required frequency and duty. The table separates gross engine power, net engine power and generator output so the correct build can be approved before quotation.

SpeedRatingEngine Power (Gross)Engine Power (Net)Generator Output (kVA)Generator Output (kWe)
1500 rpmPrime584 kW (783 hp)565 kW (758 hp)650520
1500 rpmStandby628 kW (842 hp)609 kW (817 hp)700560
1800 rpmPrime568 kW (762 hp)543 kW (728 hp)625500
1800 rpmStandby623 kW (835 hp)598 kW (802 hp)687550

Choosing the Correct Rated-Speed Version

The 1500 rpm build is normally selected for 50 Hz generator systems and provides the higher output of the two versions. The 1800 rpm build is intended for 60 Hz systems. Both fall under the same Build List family but remain separate factory configurations, so changing the genset frequency does not make the engines interchangeable.

At 100% prime load, the stated fuel consumption for both versions is 202 g/kWh. At 50% load, the stated figures are 201 g/kWh for the 1500 rpm build and 210 g/kWh for the 1800 rpm build, indicating a difference in partial-load efficiency that may matter in variable-load applications.

Build List Identification and Configuration Matching

JGBF8028 and JGB8028 refer to the same 2806A-E18TAG2 specification. JGBF8028 is the original Perkins designation assigned in 2009, while JGB8028 is the updated designation used for later production batches. The designation change relates to the production batch; parts compatibility remains the same across both Build Lists.

Build ListIdentification Notes
JGBF8028Original designation assigned by Perkins in 2009
JGB8028Updated designation used for engines from later production batches

Information to Record from the Engine Nameplate

The Build List appears on the engine nameplate, normally mounted on the rocker cover or timing case. Record the following information before requesting an engine or replacement-parts quotation:

  • Build List: JGBF8028 or JGB8028
  • Complete Engine Serial Number (ESN)
  • Required rated speed: 1500 rpm or 1800 rpm
  • Required generator frequency: 50 Hz or 60 Hz

The Build List identifies the base specification, while the ESN identifies the individual engine build. Both should be provided so the supplied engine configuration and replacement-part references can be checked before order commitment.

Replacement Parts for JGB/JGBF8028

The following original Perkins part references are listed for the 2806A-E18TAG2 Build List JGB/JGBF8028. Additional Perkins engine parts can be reviewed by category, but the complete ESN is still required before confirming an exact part number for an individual engine.

ItemPart NamePart Number
1Intake ValveCH11021
2Exhaust ValveCH11022
3Valve Spring InnerCH11489
4Valve Spring OuterCH12798 / CH11487
5Valve ColletCH10019
6Camshaft BushCH11228
7Main Bearing KitKRP3122
8Thrust Washer KitKRP3206
9Connecting Rod AssemblyCH11507
10Big End Bearing KitKRP3022
11Piston KitKRP3032
12Piston Ring KitKRP3033
13Starter MotorCH11441
14BeltCH12789
15InjectorCH12071
16Oil PumpCH10860
17Oil FilterCH10929
18Water Pump KitKRP1715

For planned cylinder-head and valve-train work, the Perkins KRP1546 top overhaul kit for 2806 TAG1/TAG2 engines is a related repair reference. Its contents and suitability for a specific JGB/JGBF8028 engine should be verified by Build List and ESN before purchase.

perkins engine parts warehouse engine parts warehouse
Perkins engine service Perkins engine service

Procurement, Export and Delivery

Engine availability and final pricing depend on the selected rated-speed configuration, order quantity and delivery terms. The typical lead time is 3–4 weeks, and the stated quotation time is within 24 hours after the required configuration and commercial information have been received.

Procurement ItemDetails
Supply SourceGenuine Perkins through a first-tier authorised distributor channel
Quotation BasisConfiguration, quantity and delivery terms
Quotation TimeWithin 24 hours after receiving the required information
Typical Lead Time3–4 weeks after order confirmation
Export DocumentationCommercial invoice, packing list, bill of lading and certificate of origin available as standard
ShippingFCL or LCL from Shenzhen, Guangzhou or Shanghai; crating and export packaging included
Pre-Shipment VerificationESN and nameplate verification before dispatch; engine test report available on request
Supply ExperienceExported to more than 30 countries
CAT C15 engine shipping CAT engine shipping Perkins engine shipping
engine parts delivering

Warranty and After-Sales Support

The stated warranty period is 12 months or the manufacturer-specified operating hours from the commissioning date, whichever comes first.

Warranty Exclusions

  1. Damage caused by incorrect installation, improper commissioning or failure to follow the Perkins Operation and Maintenance Manual applicable to JGB/JGBF8028.
  2. Normal-consumption items, including filters, belts, coolant and lubricants.
  3. Damage caused by contaminated fuel, an incorrect lubricant specification or neglected cooling-system maintenance.
  4. Modifications or repairs completed by non-authorised personnel during the warranty period.
  5. Transit damage not reported within three working days of delivery. The shipment should be inspected on receipt, and visible damage should be recorded before the delivery receipt is signed.

Warranty Claim Process

  1. Document the fault: Record the complete ESN, operating hours, fault symptoms and photographs of the affected area.
  2. Submit the claim within the warranty period: Send the documentation by email or WhatsApp and include the ESN in the subject line.
  3. Technical review: The engineering team reviews the submitted information within two business days and advises on the probable cause and next steps.
  4. Confirm the resolution: Depending on the assessment, the response may include replacement parts, coordinated repair support or an engine exchange. The proposed resolution is confirmed in writing before action is taken.

Technical and Parts Support

  • Technical inquiries by email or WhatsApp: response within one business day
  • Parts identification for JGB/JGBF8028: available on request
  • Operation and Maintenance Manual and wiring diagrams: available on request
  • Remote fault diagnosis: available by email or video call

Transit Damage Procedure

Photograph visible damage before unpacking, record it on the delivery receipt before signing and notify the supplier within three working days with supporting photographs. Do not commission a damaged engine before the damage report has been completed.

Perkins 2806A-E18TAG2 FAQ

What generator output can the 2806A-E18TAG2 support?

The 1500 rpm version is rated at 650 kVA prime and 700 kVA standby. The 1800 rpm version is rated at 625 kVA prime and 687 kVA standby. The required version depends on the genset frequency and approved operating duty.

Should I order the 1500 rpm or 1800 rpm version?

Select the 1500 rpm version for the specified 50 Hz configuration and the 1800 rpm version for the specified 60 Hz configuration. They are separate engine builds and cannot be converted between rated speeds in the field.

What is the difference between prime and standby ratings?

Prime power is intended for variable-load operation under the permitted prime-duty conditions. Standby power is the higher emergency rating and is subject to the annual operating-hour limits defined by the applicable engine duty classification.

Does the 2806A-E18TAG2 meet regulated emissions standards?

The “A” designation identifies a Fuel Optimised, non-emissions-regulated build. Buyers in markets requiring EU Stage, U.S. EPA Tier or other mandatory emissions compliance should confirm local requirements before purchasing.

Is a single customer-interface wiring harness included?

No. The standard ElectropaK build includes connector wiring to the engine ECM only. A harness integrated to a single customer interface is not included as standard.

How should the correct engine and parts configuration be confirmed?

Provide Build List JGBF8028 or JGB8028, the complete ESN and the required rated speed. These identifiers allow the engine specification and replacement-part references to be checked against the original build record.

Request a Configuration-Based Quote

Submit the following information through the contact and quotation page to confirm the correct engine build, availability, export documents and delivery terms:

  • Build List: JGB8028 or JGBF8028
  • Complete Engine Serial Number when replacing an existing engine
  • Required rated speed: 1500 rpm or 1800 rpm
  • Required frequency: 50 Hz or 60 Hz
  • Required quantity and delivery terms
  • Destination port and required export documentation

Related Product

Get Your Engine & Parts Quote
Upload your parts list or send your ESN — we reply within 30 minutes. Engine down? Need fast replacement? Contact us to check today’s stock & delivery time.
Your name *
Email *
WhatsApp / Wechat / Skype
Country
Engine Serial Number or Parts List *

sales@zebpower.com

86 13420993392

+8613420993392