The Perkins 2806A-E18TAG1A is a Fuel Optimised ElectropaK engine for prime and standby generator-set projects. Its 50 Hz and 60 Hz versions are separate factory builds rather than field-switchable settings, so rated speed, Build List and the complete ESN must be confirmed before approving an engine replacement or parts order. Standard wiring terminates at the engine ECM; a single customer-interface harness is not integrated.
Engine Configuration:
18.1L Inline-6 · Parallel Twin-Turbo · Air-to-Air Aftercooled
1500 rpm / 50 Hz Output:
600 kVA / 480 kWe Prime · 660 kVA / 528 kWe Standby
1800 rpm / 60 Hz Output:
625 kVA / 500 kWe Prime · 687 kVA / 550 kWe Standby
Emissions Category:
Fuel Optimised (A) · Non-Emissions-Regulated Build
Build Identification:
JGAF5004 / JGA5004 · Complete ESN Required for Verification
Dimensions / Dry Weight:
1808 × 2545 × 1536 mm · 2050 kg

The Perkins 2806A-E18TAG1A is an 18.1-litre, six-cylinder ElectropaK diesel engine for prime and standby generator sets. Within the broader Perkins generator-drive engine range, it is built on the Perkins 2800 Series industrial platform with parallel turbocharging, air-to-air aftercooling and direct injection.

Two separate rated-speed versions are available under Build List JGAF5004 / JGA5004: 1500 rpm for 50 Hz applications and 1800 rpm for 60 Hz applications. The 1500 rpm build is rated at 600 kVA prime and 660 kVA standby, while the 1800 rpm build is rated at 625 kVA prime and 687 kVA standby. These versions are not field-switchable, so rated speed, Build List and Engine Serial Number (ESN) should be confirmed before ordering.

Perkins 2806A-E18TAG1A Technical Specifications

ParameterValue
ConfigurationElectropaK
Cylinders6, vertical in-line
Displacement18.1 L (1104 in³)
Bore × Stroke145 × 183 mm
AspirationParallel turbocharged, air-to-air aftercooled
Combustion SystemDirect injection
Compression Ratio14.5:1
Rotation (Viewed from Flywheel)Anti-clockwise
Total Lubricating Oil Capacity62 L (16.4 US gal)
Cooling SystemWatercooled
Total Coolant Capacity61 L (16.1 US gal)
Dry Weight2050 kg (4520 lb)
Dimensions (H × L × W)1808 × 2545 × 1536 mm
Wiring Harness to Single Customer InterfaceNot integrated — connector wiring to ECM only

Rated Output at 1500 rpm and 1800 rpm

Output depends on the selected factory-rated speed. The table separates gross engine power, net engine power and generator output so buyers can confirm the correct 50 Hz or 60 Hz configuration before quotation.

SpeedRatingEngine Power (Gross)Engine Power (Net)Generator Output (kVA)Generator Output (kWe)
1500 rpmPrime540 kW (724 hp)522 kW (700 hp)600480
1500 rpmStandby593 kW (795 hp)574 kW (770 hp)660528
1800 rpmPrime568 kW (762 hp)543 kW (728 hp)625500
1800 rpmStandby623 kW (835 hp)598 kW (802 hp)687550

Build List Identification and Model Matching

JGAF5004 and JGA5004 refer to the same 2806A-E18TAG1A engine specification. JGAF5004 is the original Perkins designation assigned in 2009, while JGA5004 is the updated designation used on later production batches. The designation change reflects the production batch; parts compatibility remains identical across the two Build Lists.

Build ListIdentification Notes
JGAF5004Original designation assigned by Perkins (2009)
JGA5004Updated designation used for engines produced in later batches

Information to Record from the Engine Nameplate

The Build List is stamped on the engine nameplate, normally mounted on the rocker cover or timing case. Before requesting an engine or replacement-parts quotation, record:

  • Build List: JGAF5004 or JGA5004
  • Complete Engine Serial Number (ESN)
  • Rated speed: 1500 rpm or 1800 rpm

Providing both the Build List and ESN allows the supplied configuration and part numbers to be checked against the original engine record before order commitment. Buyers can review the wider Perkins engine parts range as a category reference, but the ESN remains necessary for exact part-number confirmation.

2806A/C-E18TAG1A Generation Index

ModelBuild List1500 rpm (50 Hz)1800 rpm (60 Hz)50 Hz Prime / Standby (kVA)60 Hz Prime / Standby (kVA)
2806A-E18TAG1AJGA / JGAF5004600 / 660625 / 687
2806C-E18TAG1AJGA / JGAF5087
2806C-E18TAG1A (E/U)JGA / JGAF8027591 / 650625 / 687

ZEB Power offers complete engines and replacement parts for the three G1-range models shown above. The exact engine model, Build List and ESN must be matched before confirming interchangeability or parts supply.

Common Replacement Parts for JGA/JGAF5004

The following original Perkins replacement-part references are listed for the 2806A-E18TAG1A Build List JGA/JGAF5004. Full parts support is available for this Build List, but the ESN should be supplied to confirm the exact part number for the individual engine. For top-end repair planning, the Perkins KRP1546 top overhaul kit is a related 2806 TAG1/TAG2 reference; applicability to a specific JGA/JGAF5004 engine must still be verified by model and ESN.

ItemPart NamePart Number
1Intake ValveCH11021
2Exhaust ValveCH11022
3Valve Spring InnerCH11489
4Valve Spring OuterCH12798 / CH11487
5Valve ColletCH10019
6Camshaft BushCH11228
7Main Bearing KitKRP3122 / KRP3118
8Thrust Washer KitKRP3206
9Connecting Rod AssemblyCH11507
10Big End Bearing KitKRP3022
11Piston KitKRP3026 / KRP3032
12Piston Ring KitKRP3021 KRP3033
13Starter MotorCH11441
14BeltCH12789
15InjectorCH12071 / CH12341
16Oil PumpCH10860
17Oil FilterCH10929
18Water Pump KitKRP1715
perkins engine parts warehouse engine parts warehouse
Perkins engine service Perkins engine service

Procurement, Export and Delivery

Engine supply is based on the required rated speed, Build List, quantity and delivery terms. Availability should be confirmed at the time of inquiry because the typical lead time is 3–4 weeks.

Procurement ItemDetails
Supply SourceGenuine Perkins through a first-tier authorised distributor
QuotationWithin 24 hours based on configuration, quantity and delivery terms
Typical Lead Time3–4 weeks after order confirmation
Export DocumentationCommercial invoice, packing list, bill of lading and certificate of origin available as standard
ShippingFCL or LCL from Shenzhen, Guangzhou or Shanghai; crating and export packaging included
Pre-Shipment VerificationESN and nameplate verification completed before dispatch; engine test report available on request
Supply ExperienceExported to more than 30 countries
CAT C15 engine shipping CAT engine shipping Perkins engine shipping
engine parts delivering

Warranty and After-Sales Support

The stated warranty period is 12 months or the manufacturer-specified operating hours from the date of commissioning, whichever comes first.

Warranty Exclusions

  1. Damage caused by incorrect installation, improper commissioning or failure to follow the Perkins Operation and Maintenance Manual for JGA/JGAF5004.
  2. Normal-consumption items, including filters, belts, coolant and lubricants.
  3. Damage caused by contaminated fuel, an incorrect lubricant specification or neglected cooling-system maintenance.
  4. Modifications or repairs completed by non-authorised personnel during the warranty period.
  5. Transit damage not reported within three working days of delivery. Shipments should be inspected on receipt, and visible damage should be documented before the delivery receipt is signed.

Warranty Claim Process

  1. Document the fault: Record the ESN, operating hours, fault symptoms and photographs of the affected area.
  2. Submit the claim within the warranty period: Send the documentation by email or WhatsApp and include the ESN in the subject line.
  3. Technical review: The engineering team reviews the submission within two business days and advises on the probable cause and next steps.
  4. Resolution: Depending on the assessment, the response may include replacement parts, coordinated repair support or an engine exchange. The proposed resolution is confirmed in writing before action is taken.

Technical and Parts Support

  • Technical inquiries by email or WhatsApp: response within one business day
  • Parts identification for JGA/JGAF5004: available on request
  • Operation and Maintenance Manual and wiring diagrams: available on request
  • Remote fault diagnosis: available by email or video call

Transit Damage Procedure

Photograph visible damage before unpacking, note it on the delivery receipt before signing and notify the supplier within three working days with supporting photographs. Do not commission a damaged engine before the damage report has been completed.

Perkins 2806A-E18TAG1A FAQ

What is the difference between the 1500 rpm and 1800 rpm versions?

Both versions use Build List JGAF5004 / JGA5004, but they are separate factory builds and cannot be switched between rated speeds in the field. The 1500 rpm version is rated at 600 kVA prime and 660 kVA standby; the 1800 rpm version is rated at 625 kVA prime and 687 kVA standby.

What does the “A” prefix mean in 2806A-E18TAG1A?

The “A” prefix identifies the Fuel Optimised, non-emissions-regulated version of the engine, distinguishing it from regulated emissions variants intended for other markets.

Why does the engine use parallel turbocharging?

The parallel turbocharging system, combined with air-to-air aftercooling, supports high power density and more consistent output at altitude than a comparable single-turbo arrangement.

What is the fuel consumption of the 2806A-E18TAG1A?

At prime rating, stated fuel consumption is approximately 199–203 g/kWh across 50–110% load at 1500 rpm and approximately 201–210 g/kWh at 1800 rpm.

Is a single customer-interface wiring harness included?

No. The standard ElectropaK configuration includes connector wiring to the engine ECM only. A wiring harness integrated to a single customer interface is not included as standard.

How should the correct Build List and configuration be confirmed?

Provide the Build List, JGAF5004 or JGA5004, together with the complete ESN and required rated speed. These identifiers can be checked against the original build record before the quotation is finalised.

Is an Electro unit version available?

No Electro unit variant is offered under Build List JGAF5004. This model is supplied in ElectropaK configuration.

Request a Configuration-Based Quote

To confirm the correct engine specification, availability, export documents and delivery terms through the contact and quotation page, provide:

  • Build List: JGA5004 or JGAF5004
  • Complete Engine Serial Number when replacing an existing engine
  • Required rated speed: 1500 rpm or 1800 rpm
  • Required quantity and delivery terms
  • Destination port and required export documentation

Related Product

Get Your Engine & Parts Quote
Upload your parts list or send your ESN — we reply within 30 minutes. Engine down? Need fast replacement? Contact us to check today’s stock & delivery time.
Your name *
Email *
WhatsApp / Wechat / Skype
Country
Engine Serial Number or Parts List *

sales@zebpower.com

86 13420993392

+8613420993392