Perkins 2506A-E15TAG1 Fuel Optimised Genset Engine – 455/500 kVA
Perkins 2506A-E15TAG1 Fuel Optimised Genset Engine – 455/500 kVA

Perkins 2506A-E15TAG1 Fuel Optimised Genset Engine – 455/500 kVA

Perkins 2506A-E15TAG1 is a 15.2L Fuel Optimised ElectropaK engine for 1500 rpm / 50 Hz generator sets. It delivers 364 kWe / 455 kVA prime and 400 kWe / 500 kVA standby power, with supply and parts matched by Build List and complete ESN.
Engine Configuration:
15.2L Inline-6 Turbocharged ElectropaK Diesel
Prime Rating:
364 kWe / 455 kVA at 1500 rpm
Standby Rating:
400 kWe / 500 kVA at 1500 rpm
Frequency:
50 Hz Generator-Set Configuration
Emissions Position:
Fuel Optimised
Engine Identification:
MGAF5076 / MGAF5008 / MGA5076 / MGA5008 + Complete ESN
Commercial Support:
Typical 3–4 Week Lead Time · Quote Within 24 Hours · 12-Month Warranty
Supply Experience:
First-Tier Distributor Channels · Exported to 30+ Countries

The Perkins 2506A-E15TAG1 is a 15.2 L, six-cylinder ElectropaK diesel engine for stationary 50 Hz power-generation projects. At 1500 rpm, it delivers 364 kWe / 455 kVA prime power and 400 kWe / 500 kVA standby power.

This Fuel Optimised 2500 Series engine combines mechanically actuated unit injectors with full-authority electronic control, turbocharging and air-to-air charge cooling. Engine supply and replacement parts should be confirmed by the complete Build List, Engine Serial Number and generator-set application.

  • 15.2 L vertical inline six-cylinder diesel engine
  • Turbocharged and air-to-air charge cooled
  • 1500 rpm / 50 Hz generator-set configuration
  • 364 kWe / 455 kVA prime output
  • 400 kWe / 500 kVA standby output
  • Fuel Optimised emissions position
  • ElectropaK package for generator integration
  • Build List and complete ESN verification for supply and parts

Typical Lead Time: 3–4 weeks, subject to stock and final configuration.
Quotation: Configuration-based quote within 24 hours.
Supply Channel: Genuine Perkins products supported by first-tier distributor channels.
Export Experience: Supplied to customers in more than 30 countries.
Warranty: 12 months, subject to confirmed supply condition and contract terms.

Send the engine dataplate, Build List and complete ESN for a configuration-specific quotation.

Perkins 2506A-E15TAG1 Technical Specifications

ParameterSpecificationSelection Note
PackageElectropaK generator-drive engineEngine package only; not a complete diesel generator set.
Configuration6 cylinders, vertical inline, four-strokeDesigned for stationary electric-power generation.
Displacement15.2 L (927.6 in³)Commonly referred to as the Perkins 15-litre platform.
Bore × stroke137 × 171 mmInternal components still require Build List and ESN verification.
Compression ratio16.0:1Do not use compression ratio alone to identify overhaul parts.
AspirationTurbocharged and air-to-air charge cooledCooling performance must suit altitude, ambient temperature and enclosure airflow.
CombustionDirect injectionFuel-system components must match the approved engine record.
Fuel controlMechanically actuated unit injectors with full-authority electronic controlECM calibration, injectors, sensors and harness must match the rating.
Rated speed on this page1500 rpmConfigured for 50 Hz generator-set operation.
GoverningISO 8528-5 class G3 with isochronous capabilityCompleted genset response also depends on controller and alternator integration.
RotationAnti-clockwise from the flywheel endConfirm coupling and alternator arrangement before replacement.
Lubricating-oil capacityApproximately 62 LFinal service quantity depends on sump and installation.
Coolant capacityApproximately 58 LThe completed generator-set cooling circuit may require additional coolant.
Emissions positionFuel OptimisedNot presented as compliant with a harmonised regulated emissions tier.
Exhaust aftertreatmentNone specifiedDestination-country and site requirements must be checked before supply.

1500 rpm / 50 Hz Power Output

This page covers the TAG1 1500 rpm configuration. Final electrical output depends on the approved engine rating, alternator efficiency, controller settings, cooling system and site derating.

DutyGross Mechanical OutputNet Mechanical OutputTypical Electrical OutputOperating Position
Prime412 kWm (approximately 552 hp)396 kWm (approximately 531 hp)364 kWe / 455 kVAVariable-load operation with extended annual use under the applicable prime-power definition.
Standby451 kWm (approximately 605 hp)434 kWm (approximately 582 hp)400 kWe / 500 kVAEmergency operation when the normal electrical supply fails.

The kVA values assume a typical 0.8 power factor and approximately 92% alternator efficiency. Standby output should not be selected as a continuous base-load rating.

Prime and Standby Duty Selection

DutyTypical UseOperating LimitationSelection Risk
Prime powerVariable-load generation where the engine is a regular power sourceUnlimited annual hours within the published load-factor definition; 10% overload may be available for 1 hour in every 12 hoursDo not size the set only from the maximum connected load.
Standby powerEmergency backup when the normal utility or primary source failsLimited annual use under the applicable rating definition; no overloadDo not use the 500 kVA standby rating for continuous production power.

Reference Fuel Consumption at 1500 rpm

Fuel-use figures are planning references and may vary with the approved Build List, load profile, alternator efficiency, fuel density, fan demand, ambient temperature and altitude.

Operating PointApproximate Fuel UsePlanning Note
Standby ratingApproximately 104 L/hUse only for emergency standby calculations.
100% prime loadApproximately 95 L/hUseful for full-load fuel-tank and operating-cost planning.
75% prime loadApproximately 72 L/hOften more representative of variable-load operation.
50% prime loadApproximately 50 L/hDo not extrapolate linearly to lower loads.

For final tank sizing, request the rating sheet for the confirmed engine and calculate against the actual hourly load profile.

ElectropaK Equipment and Installation Data

ElectropaK is a generator-drive engine package rather than a complete genset. The exact supplied scope varies by Build List, production date and quotation.

SystemCommon Family EquipmentOrder Check
Air inletEngine-mounted air filterConfirm rain hood, restriction indicator and installation air path if required.
CoolingGear-driven circulating pump, belt-driven fan and radiator with air-to-air charge coolerConfirm whether the radiator is mounted or supplied loose and verify ambient capability.
Electrical24 V starter, 24 V 70 A charging alternator, ECM, wiring looms and sensorsConfirm starter arrangement, connectors and customer-controller interface.
ProtectionThree-level engine protection systemConfirm shutdown and alarm integration with the selected controller.
FlywheelSAE J620 size 14 high-inertia flywheelConfirm torsional compatibility with the selected AC alternator.
Flywheel housingSAE ½ flywheel housingCheck coupling, adaptor and alternator-interface dimensions.
Fuel systemFuel cooler, primary filter/water separator and replaceable Ecoplus elementsConfirm connection points and customer-supplied day-tank arrangement.
LubricationWet sump, oil cooler, filler, dipstick and full-flow Ecoplus filterConfirm sump orientation and service access.
MountingFront engine mounting bracketConfirm base-frame design, rear support and alignment procedure.

Reference Package Dimensions

ItemReference ValueEngineering Note
LengthApproximately 2657 mmFinal dimensions depend on the selected equipment and options.
WidthApproximately 1120 mmAllow additional service and airflow clearances.
HeightApproximately 1718 mmCheck lifting, exhaust, radiator and roof clearance.
Dry weightApproximately 1633 kg (3601 lb)Confirm shipping weight and center of gravity for the quoted engine.

Request a configuration drawing before finalising the base frame, enclosure, lifting arrangement or service clearances.

Build List and ESN Verification

The model designation identifies the engine family and TAG1 power node, but it does not define every fitted component. Use the complete Build List and ESN to verify the ECM, cooling equipment, electrical system, flywheel arrangement and replacement parts.

Identification ItemExamplePurpose
Engine model2506A-E15TAG1Identifies the base engine family and TAG1 rating.
Build ListMGAF5076, MGAF5008, MGA5076 or MGA5008Identifies the production specification and fitted component combination.
Engine Serial NumberComplete ESN from the dataplateLinks the engine to its individual manufacturing and service record.
Rated speed and duty1500 rpm, prime or standbyPrevents selection of the wrong output or calibration.
Dataplate photographClear image of every fieldReduces transcription errors during quotation and parts matching.

MGAF and MGA Build List References

MGAF5076 / MGAF5008 and MGA5076 / MGA5008 may appear as related Build List references, but the codes should not be treated as universally interchangeable from the suffix alone. Confirm the complete Build List, ESN and applicable component supersessions before approving an engine or part.

1500 rpm and 1800 rpm Family Configurations

The wider 2506A-E15TAG family includes both 1500 rpm and 1800 rpm products, but TAG1 is the 1500 rpm specification covered on this page. For a 60 Hz replacement project, verify the correct TAG model, ECM calibration, AC alternator, voltage, cooling and controller settings instead of assuming a controller-only conversion.

2506A, 2506C and 2506D Compatibility

The 2506A, 2506C and 2506D variants share a common 15.2 L platform, but different emissions positions, calibrations and supplied equipment can affect complete-engine and component compatibility.

Compatibility CheckItems to Compare
Mechanical interfaceMounts, flywheel, housing, coupling, dimensions and alternator alignment
Electrical interfaceECM, harness, starter voltage, charging alternator, sensors and controller connections
Rating1500 rpm, 50 Hz, prime or standby duty and ECM calibration
CoolingRadiator, charge cooler, fan, enclosure airflow and ambient capability
Emissions positionFuel Optimised, regulated emissions requirement and destination-market acceptance
PartsBuild List, ESN, existing part number and current supersession

Any A-to-C, C-to-D or D-to-A replacement should be handled as an engineering substitution rather than a direct model-name replacement.

Replacement Parts and Fitment Control

Do not rely on one fixed parts list for every 2506A-E15TAG1. Production changes and superseded part numbers can affect fitment, especially for bearings, pistons, starters, filters, pumps and electronic components.

Parts GroupTypical RequirementsMatching Information
Routine serviceOil filters, fuel filters, water-separator elements, belts and sealsBuild List + ESN + service interval
Fuel systemLift pump, fuel cooler, filter housing, injectors and linesBuild List + ESN + existing component number
Cooling systemCoolant pump, thermostat, fan, belts, radiator and charge-cooler partsBuild List + ESN + cooling-package configuration
Starting and chargingStarter, charging alternator, solenoid, sensors and wiringSystem voltage + Build List + ESN + connector details
Cylinder head and valve trainValves, springs, guides, rocker parts and head gasketBuild List + ESN + inspection results
Overhaul componentsPistons, rings, liners, bearings, thrust washers and gasket setsBuild List + ESN + standard or repair-size requirement
Electronic controlECM, harness, speed, pressure and temperature sensorsECM number + calibration + Build List + ESN

Reference Part Numbers from Existing Records

PartReference NumberFitment Status
Main bearing kitKRP3118 / KRP3122Confirm standard or repair size by Build List and ESN.
Thrust washer kitKRP3206Verify crankshaft and block specification.
Cylinder linerCH11180Match to the confirmed piston and block configuration.
Big-end bearing kitKRP3016Confirm journal condition and required size.
Piston kitKRP3030Verify piston specification and cylinder condition.
Piston-ring kitKRP3018Match to the confirmed piston and liner specification.
Lift pumpKRP1721Verify the fitted fuel-system arrangement.
Starter motorCH12807 / CH11089 / CH12045Confirm voltage, mounting and electrical connections.
Charging alternatorCH11087Verify output, mounting and connector arrangement.
Fuel filtersCH10930 / CH10931Confirm primary and secondary filter positions.
Perkins engine parts warehouse and stock controlDiesel engine parts storage and order preparation
Perkins diesel engine service and inspectionPerkins engine maintenance and parts verification

Supply, Logistics and Warranty

Commercial support is a key part of the supply offer. Final delivery and warranty terms should still be recorded in the quotation so the buyer can match them to the selected engine condition, quantity and destination.

Commercial AdvantageSupply Position
Supply channelGenuine Perkins products supported by first-tier distributor channels
Quotation responseConfiguration-based quotation within 24 hours after receiving the required engine and delivery information
Typical lead time3–4 weeks, subject to stock, final configuration, inspection scope and quantity
Export experienceInternational supply experience covering more than 30 countries
Export documentationCommercial invoice, packing list, transport document and certificate of origin where applicable
ShippingFCL or LCL shipment with export packing from the confirmed dispatch location
Pre-shipment controlDataplate, Build List, ESN, supplied accessories and visible condition recorded before dispatch
Warranty12 months or the operating-hour limit stated in the contract, subject to confirmed engine condition and warranty terms

Warranty Records and Claim Information

RecordRequired Information
Engine identityModel, complete Build List, ESN and dataplate photograph
CommissioningDate, installation record, operating parameters and responsible technician
MaintenanceOperating hours, oil, coolant, filters and scheduled service records
Fault evidenceFault code, symptoms, photographs, video and controller data where available
Transport damagePhotographs before unpacking and notation on the delivery receipt

Warranty generally excludes incorrect installation, improper commissioning, contaminated fuel, unsuitable lubricant or coolant, unauthorised modification, normal consumables and unreported transport damage. The signed quotation and warranty document remain the controlling terms.

Heavy diesel engine prepared for export shipmentIndustrial engine export packing and logistics handlingPerkins diesel engine secured for international delivery
Perkins engine parts packed for international delivery

Information Required for a Quotation

Required InformationExample
Required productComplete engine, replacement engine, long block or parts
Engine identity2506A-E15TAG1, complete Build List, ESN and dataplate photo
Duty and output364 kWe / 455 kVA prime or 400 kWe / 500 kVA standby
Frequency and speed50 Hz / 1500 rpm
Replacement applicationExisting genset, AC alternator, controller and installation photographs
Quantity and destinationRequired quantity, country, city or seaport and preferred Incoterm
Special requirementsInspection, testing, packing, documentation and warranty requirements

Frequently Asked Questions

What output does the 2506A-E15TAG1 provide?

At 1500 rpm, it provides 364 kWe / 455 kVA prime power and 400 kWe / 500 kVA standby power for a typical 50 Hz generator-set application.

What does Fuel Optimised mean?

It is Perkins’ emissions position for this engine family. It should not automatically be described as compliant with a specific regulated emissions tier without destination-specific documentation.

Is ElectropaK a complete generator set?

No. ElectropaK is a generator-drive engine package. The AC alternator, controller, base frame, fuel tank, starting batteries, silencer and enclosure are included only when specifically stated in the quotation.

Can the TAG1 engine be used at 1800 rpm?

This page covers the 1500 rpm TAG1 specification. For a 60 Hz project, verify the correct 1800 rpm model and the complete engine, alternator, controller, voltage and cooling configuration.

Are MGAF5076 and MGA5076 automatically interchangeable?

No universal assumption should be made. Compare the complete Build List, ESN, rating and applicable part supersessions before approving an engine or component.

Can parts be ordered using only “2506A-E15TAG1”?

The complete Build List and ESN are required for reliable identification. Existing part numbers and component photographs should also be supplied when available.

What fuel and lubricating oil should be used?

Use diesel fuel and lubricating oil that meet the specifications stated in the applicable Perkins Operation and Maintenance Manual for the confirmed engine. Fuel quality, viscosity grade and service interval should be selected for the local climate and operating conditions.

Is the typical lead time three to four weeks?

Yes, the typical quoted lead time is three to four weeks. Final timing is confirmed against stock, configuration, inspection scope, quantity and destination.

What warranty is provided?

A 12-month warranty is available subject to the confirmed supply condition, operating-hour limit, commissioning requirements and contract terms.

Request a 2506A-E15TAG1 Configuration Check

Send the engine dataplate, complete Build List, ESN, required duty, quantity and destination. For replacement projects, also provide photographs of the existing engine, alternator, controller, mounts and connection points.

Submit the engine details for configuration, supply-scope and parts-compatibility review.

Get Your Engine & Parts Quote
Upload your parts list or send your ESN — we reply within 30 minutes. Engine down? Need fast replacement? Contact us to check today’s stock & delivery time.
Your name *
Email *
WhatsApp / Wechat / Skype
Country
Engine Serial Number or Parts List *

sales@zebpower.com

86 13420993392

+8613420993392